<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-11-23T03:04:35Z</responseDate><request verb="GetRecord" identifier="oai:digital.lib.washington.edu:1773/20207" metadataPrefix="dim">https://digital.lib.washington.edu/server/oai/request</request><GetRecord><record><header><identifier>oai:digital.lib.washington.edu:1773/20207</identifier><datestamp>2025-01-07T21:14:51Z</datestamp><setSpec>com_1773_4888</setSpec><setSpec>col_1773_4940</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="advisor" lang="en_US">Ledoux, William R</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="author" lang="en_US" authority="5b1bc753-2453-4622-a36d-bc0839d9aaca" confidence="-1">Stebbins, Michael Jay</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2012-08-10T17:14:10Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2013-02-07T12:03:24Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued">2012-08-10</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="submitted" lang="en_US">2012</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="other" lang="en_US">Stebbins_washington_0250O_10183.pdf</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">http://hdl.handle.net/1773/20207</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Thesis (Master's)--University of Washington, 2012</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">&lt;italic>Background&lt;/italic>: People  with  diabetes  account  for  just  over  8%  of  the  US  population,  but  they  undergo approximately 63% of all non-traumatic lower limb amputations, or 65,700 amputations per year.  Eighty-five percent of those amputations are preceded by a foot ulcer.  Diabetes has been shown to increase the stiffness of the plantar soft tissue in cadaveric samples, which could cause shifting of the magnitude and/or location of peak stresses within the foot. The purpose of this research project was to develop a magnetic resonance imaging (MRI) compatible, dynamic loading device that used cardiac-gated MRI imaging to obtain &lt;italic>in vivo &lt;/italic>force versus deformation data for the plantar soft tissue.  The resulting data will be used as inputs to an inverse finite element (FE) analysis to solve for soft tissue material properties in a patient-specific FE model. &lt;italic>Methods &lt;/italic>: A computer-controlled, MRI-compatible loading device was designed, built, and tested in the laboratory  to  quantify  performance  parameters  and  ensure  safe  operation  of  the  device before proceeding to pilot human studies.  A test subject was loaded by the device while tissue  thickness  changes  were  measured  via  an  ultrasound  transducer  attached  to  the loading device.  Finally, an MRI pilot study was completed in which the heel of a test subject was  dynamically  loaded  in  compression  at  a  0.2  Hz  rate  inside  an  MRI  while  three-dimensional (3-D) images were obtained.  &lt;italic>Results&lt;/italic>: The  amount  of  test  subject  movement  and  shift  within  the  apparatus  under  loading  were determined  during  ultrasound  testing,  as  was  a  displacement  calibration  curve  for  normal human soft tissue.  Force on the foot and displacement of the soft tissue during 12 phases of loading and unloading were obtained from the MRI pilot study, from which the stiffness of the plantar skin and adipose tissue was calculated to be 55 N/mm. &lt;italic>Conclusion &lt;/italic>: An  MRI-compatible,  computer-controlled  loading  device  was  successfully  designed,  built, and used in a pilot human study.  As the first device of its kind, it will prove beneficial to the research  and  medical  communities  by  increasing  understanding  of  the  initiation  of  foot ulcers in people with diabetes.</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype" lang="en_US">application/pdf</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en_US">en_US</dim:field>
   <dim:field mdschema="dc" element="rights" lang="en_US">Copyright is held by the individual authors.</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">FEA; inverse; material properties; plantar; soft tissue</dim:field>
   <dim:field mdschema="dc" element="subject" qualifier="other" lang="en_US">Biomechanics</dim:field>
   <dim:field mdschema="dc" element="subject" qualifier="other" lang="en_US">Mechanical engineering</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">Obtaining Material Properties of the Plantar Soft Tissue for  a Patient-Specific Finite Element Model of the Foot</dim:field>
   <dim:field mdschema="dc" element="type" lang="en_US">Thesis</dim:field>
   <dim:field mdschema="dc" element="embargo" qualifier="terms" lang="en_US">Restrict to UW for 6 months -- then make Open Access</dim:field>
   <dim:field mdschema="others" element="access-status">open.access</dim:field>
</dim:dim>
</metadata></record></GetRecord></OAI-PMH>