<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-11-22T21:45:12Z</responseDate><request verb="GetRecord" identifier="oai:digital.lib.washington.edu:1773/23342" metadataPrefix="dim">https://digital.lib.washington.edu/server/oai/request</request><GetRecord><record><header><identifier>oai:digital.lib.washington.edu:1773/23342</identifier><datestamp>2025-01-08T03:19:05Z</datestamp><setSpec>com_1773_4888</setSpec><setSpec>col_1773_19658</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="advisor" lang="en_US">Wu, David</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="author" lang="en_US" authority="672b6522-06e6-4753-8a81-7ac99e1cfc72" confidence="-1">Huang, Hsin-Hsuan</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2013-07-25T17:45:24Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2013-07-25T17:45:24Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued">2013-07-25</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="submitted" lang="en_US">2013</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="other" lang="en_US">Huang_washington_0250O_11895.pdf</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">http://hdl.handle.net/1773/23342</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Thesis (Master's)--University of Washington, 2013</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">Introduction: Aptamers are engineered oligonucleotides that can be selected to bind with high specificity and affinity. As aptamers are cost-effective (estimated to be ~1,000-fold cheaper than antibodies) and also temperature-stable, aptamers may be useful in resource-limited settings for T-cell subset quantification. Here, we evaluated the performance characteristics of a CD4 aptamer for T-cell subset quantification. Methods: A CD4-biotinylated-streptavidin-PE aptamer provided by SomaLogic, Boulder, CO was combined with CD3-PC5, CD8-ECD and CD45-FITC antibodies in the multicolor flow cytometric assay; a CD4-A594 antibody was also added as an internal control for the CD4 aptamer. Residual patient samples were evaluated using the aptamer versus antibody reagents. Both the proportion of CD4 T cell and absolute CD4 T cell count were analyzed to evaluate the clinical performance of the aptamer reagent. Results and Conclusion: The CD4 aptamer showed comparable results to the established single platform method, which uses CYTO-STAT reagent (CD45F/CD4RD1/CD8ECD/CD3PC5) and an FC-500 flow cytometry system, with r2 >0.92 of CD4 T-cell% measurement,. Further, both the percentage of CD4 T cells and absolute T-cell count showed excellent agreement over the range of T cell proportions (8.6% to 50%) and absolute T-cell counts (150 cells/ul to 1342 cells/ul) as assessed by the CD4 aptamer as compared to an internal CD4-A594 antibody control, with r2 >0.99 and 9 cells /ul in mean difference. Our results suggest that a CD4 aptamer can perform comparably to an established CD4 antibody for CD4 T-cell subset quantitation and supports further development of aptamers as potential cost-effective reagents in resource-limited regions.</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype" lang="en_US">application/pdf</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en_US">en_US</dim:field>
   <dim:field mdschema="dc" element="rights" lang="en_US">Copyright is held by the individual authors.</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">Aptamer; CD4 Counts; Flow Cytometry</dim:field>
   <dim:field mdschema="dc" element="subject" qualifier="other" lang="en_US">Medicine</dim:field>
   <dim:field mdschema="dc" element="subject" qualifier="other" lang="en_US">Health sciences</dim:field>
   <dim:field mdschema="dc" element="subject" qualifier="other" lang="en_US">laboratory medicine</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">Evaluation of a CD4-aptamer for Flow Cytometry-based Enumeration of T-cell Subsets</dim:field>
   <dim:field mdschema="dc" element="type" lang="en_US">Thesis</dim:field>
   <dim:field mdschema="dc" element="embargo" qualifier="terms" lang="en_US">No embargo</dim:field>
   <dim:field mdschema="others" element="access-status">open.access</dim:field>
</dim:dim>
</metadata></record></GetRecord></OAI-PMH>