<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-11-23T10:53:36Z</responseDate><request verb="GetRecord" identifier="oai:digital.lib.washington.edu:1773/38613" metadataPrefix="dim">https://digital.lib.washington.edu/server/oai/request</request><GetRecord><record><header><identifier>oai:digital.lib.washington.edu:1773/38613</identifier><datestamp>2025-01-08T06:28:47Z</datestamp><setSpec>com_1773_4888</setSpec><setSpec>col_1773_4915</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="advisor">Otis, Brian P</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="author" authority="3cbea34d-f272-4d4b-8f46-d5a70027d099" confidence="300">Morrison, Timothy David</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2017-05-16T22:12:39Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2017-05-16T22:12:39Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="submitted">2017-03</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="other">Morrison_washington_0250E_16860.pdf</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">http://hdl.handle.net/1773/38613</dim:field>
   <dim:field mdschema="dc" element="description">Thesis (Ph.D.)--University of Washington, 2017-03</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract">This document presents various techniques and systems for recording biological signals. Specifically electrocardiography (ECG), electromyography (EMG) and single-unit neuron recording applications are discussed. These recording techniques sense electrical potentials generated by biological functions which are then amplified and sampled using electronic devices. The evolution of this biosignal monitor electronic device over four design genera- tions highlights the advantages of utilizing integrated circuits (ICs) designed solely for the given application. The final design combines the benefits of a low power IC and the highly customizable nature of a microconroller. Thanks to its high level of customizability after fabrication this system is ideal for innumerable applications in the field of biosignal moni- toring by lowering the technically barrier and development time required for many future biosignal monitoring applications.</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso">en_US</dim:field>
   <dim:field mdschema="dc" element="rights">none</dim:field>
   <dim:field mdschema="dc" element="subject" />
   <dim:field mdschema="dc" element="subject">Electrical engineering</dim:field>
   <dim:field mdschema="dc" element="subject" qualifier="other">Electrical engineering</dim:field>
   <dim:field mdschema="dc" element="title">Integrated Circuit and System Design for Wireless Biosignal Monitoring</dim:field>
   <dim:field mdschema="dc" element="type">Thesis</dim:field>
   <dim:field mdschema="dc" element="embargo" qualifier="terms">Open Access</dim:field>
   <dim:field mdschema="others" element="access-status">open.access</dim:field>
</dim:dim>
</metadata></record></GetRecord></OAI-PMH>