<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-11-22T15:55:10Z</responseDate><request verb="GetRecord" identifier="oai:digital.lib.washington.edu:1773/53395" metadataPrefix="dim">https://digital.lib.washington.edu/server/oai/request</request><GetRecord><record><header><identifier>oai:digital.lib.washington.edu:1773/53395</identifier><datestamp>2026-06-11T20:28:33Z</datestamp><setSpec>com_1773_4888</setSpec><setSpec>col_1773_4895</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="advisor">Wang, Ruikang</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="author">Shi, Yaping</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2025-08-01T22:15:56Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued">2025-08-01</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="submitted">2025</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="other">Shi_washington_0250E_28269.pdf</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">https://hdl.handle.net/1773/53395</dim:field>
   <dim:field mdschema="dc" element="description">Thesis (Ph.D.)--University of Washington, 2025</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract">Recent advances in optical coherence tomography (OCT) have significantly broadened their 
utility in biomedical imaging, particularly for the diagnosis and monitoring of vascular-related 
and microstructural diseases. However, clinical OCT systems remain constrained by limited 
imaging speed, shallow ranging distance, narrow field of view (FoV), and the lack of robust 
functional imaging capabilities. These limitations hinder broader in vivo clinical applications 
of OCT. In this study, we develop a high-speed, long-range, wide-field swept-source OCT (SS
OCT) system based on a 600 kHz micro-mlectro-mechanical system vertical-cavity durface
emitting laser (MEMS-VCSEL) laser, designed to deliver high-fidelity morphological and 
functional imaging. To overcome the depth limitation inherent in conventional k-clock 
acquisition, we develop a multi-channel delay sampling technique that splits the analog OCT 
signal into N-channel time-delayed electrical paths. This method increases the effective k-space 
sampling density without altering k-clock triggering, thereby doubling the imaging depth 
without compromising acquisition speed or resolution. To further enhance imaging 
performance, we introduce the concept of electrical dispersion, which arises from the nonlinear 
phase response of electronic components operating under high-speed k-clock triggering. A 
global k-space compensation algorithm is proposed to mitigate this distortion, and a vector 
field-based distortion correction technique is implemented to restore spatial fidelity in wide
field scans. Together, these methods enable high-quality structural and optical coherence 
tomography angiography (OCTA) imaging across a lateral FoV of 42 × 42 mm² and an extended 
axial range of 36 mm. To address challenges in imaging samples with complex surface 
topography, such as the oral cavity, we propose an adaptive contour tracking and scanning 
strategy. This approach integrates an electrically tunable lens and motorized optical delay line 
with real-time surface profiling to maintain focus and SNR across curved surfaces. 
Experimental validation confirms improved image consistency and flow visualization across 
large and irregularly contoured regions. Finally, we incorporate a novel fiber-based 
polarization-sensitive OCT (PS-OCT) system based on the platform. To address the instability 
of the input state of polarization in single-input fiber configurations, we introduce a real-time 
Stokes vector feedback mechanism that dynamically stabilizes incident circular polarization at 
the sample surface. This innovation enables reliable birefringence imaging under wide-field 
and handheld conditions. Together, these system-level advancements result in an OCT platform 
capable of high-speed, long-range, wide-field, and functionally enhanced imaging. The 
proposed system demonstrates significant potential for clinical applications in oral health 
assessment and other settings requiring comprehensive, real-time evaluation of tissue structure, 
microvasculature, and optical anisotropy.</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso">en_US</dim:field>
   <dim:field mdschema="dc" element="relation" qualifier="haspart">Anterior oral cavity Structure.avi; video; Wide field slicing view of the anterior oral cavity’s structure.</dim:field>
   <dim:field mdschema="dc" element="relation" qualifier="haspart">Anterior oral cavity Blood Flow.avi; video; Wide field slicing view of the anterior oral cavity’s blood flow.</dim:field>
   <dim:field mdschema="dc" element="relation" qualifier="haspart">Flow_changeView.avi; video; Wide field slicing view of the side oral cavity’s blood flow achieved with adaptive contour tracking scanning OCT.</dim:field>
   <dim:field mdschema="dc" element="rights">none</dim:field>
   <dim:field mdschema="dc" element="subject">functional</dim:field>
   <dim:field mdschema="dc" element="subject">high speed</dim:field>
   <dim:field mdschema="dc" element="subject">long range</dim:field>
   <dim:field mdschema="dc" element="subject">optical coherence tomography</dim:field>
   <dim:field mdschema="dc" element="subject">swept source</dim:field>
   <dim:field mdschema="dc" element="subject">wide field</dim:field>
   <dim:field mdschema="dc" element="subject">Bioengineering</dim:field>
   <dim:field mdschema="dc" element="subject">Optics</dim:field>
   <dim:field mdschema="dc" element="subject">Ophthalmology</dim:field>
   <dim:field mdschema="dc" element="subject" qualifier="other">Bioengineering</dim:field>
   <dim:field mdschema="dc" element="title">Development and Application of High-speed and Wide-field Functional Swept Source Optical Coherence Tomography</dim:field>
   <dim:field mdschema="dc" element="type">Thesis</dim:field>
   <dim:field mdschema="dc" element="embargo" qualifier="terms">Restrict to UW for 1 year -- then make Open Access</dim:field>
   <dim:field mdschema="dc" element="embargo" qualifier="lift">2026-08-01T22:15:56Z</dim:field>
   <dim:field mdschema="others" element="access-status">embargo</dim:field>
</dim:dim>
</metadata></record></GetRecord></OAI-PMH>